Signaling: treat a connection without pings as dead and reconnect (#19)

Only a close frame or read error ended the signaling loop, so a half-open
socket after suspend or a NAT drop left the host believing it was online.
Per Engine.IO 4, report Disconnected when no ping arrives within the
server's pingInterval + pingTimeout so the existing reconnect loop runs.

Co-Authored-By: Claude Opus 5.5 <[email protected]>
This commit is contained in:
VallierDevandClaude Opus 5.5 committed 2026-10-16 11:24:51 +08:00
1 parent d5e9007dd6
commit aeaf818c39
4 files changed
+55 -2

No files matched your search

+14
View File
@@ -0,0 +1,14 @@
信令断线检测:主机休眠恢复或网络悄悄断开后自动重新上线。/ Detect dead signaling connections and reconnect.
### 修复 / Fixed
- **主机显示在线但控制端看不到、只能手动重启服务**(#19,感谢 @Keinns):之前只有收到关闭帧或读错误才判定信令断开;
系统休眠恢复、NAT 超时等造成的半开连接会让主机一直以为自己在线。现在按 Engine.IO 协议,超过服务器下发的
`pingInterval + pingTimeout`(目前约 33 秒)没收到心跳就判定断线,走已有的自动重连。日志:`Signaling heartbeat lost`。
已用模拟的「不发心跳」信令服务器单元测试验证;真实休眠恢复场景未实测。
Signaling now treats a connection without pings for pingInterval + pingTimeout as dead and reconnects.
Unit-tested against a silent mock server; real suspend/resume not yet measured.