The X11 engine has one process-wide display connection, but every
ScreenCapture closed it on drop. During guest assistance the device
init's screen-size probe created and dropped a capture after the main
one, closing the display under it: the stream stopped with
"X11 display wake failed" and the viewer got no video. A capture
replaced after a resize had the same hazard. Count live X11 captures
and close only on the last drop.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
* fix(portal): establish locked desktop control before capture
* test(portal): preserve v4 pixel inventory after deferred capture settings
* fix(control): refresh lock state after viewer Echo handshake
* fix(portal): announce desktop target before locked capture wait
* ci: run the desktop_power native test under ASan/UBSan
Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
* input: skip the Portal release sweep while no session is bound
The first locked connection creates its peer before any Portal exists; the sweep
then logged two failed injections and a 'reset incomplete' warning for nothing.
Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
* docs: describe locked cold connections, auto unlock limits and iPhone status
Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
* fix(portal): treat a cached screen with a closed Portal session as not ready
begin() now marks the state as waiting when the cached session is dead, and
permission/video/clipboard consumers honor it instead of reporting Allow and
starting the stale video path before maintain() has rebuilt capture.
Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
* fix(portal): gate input on a ready desktop and share recovery backoff
Input dispatch kept only the cached screen and dropped State.waiting, so a closed
Portal passed the gate once the screen unlocked. The supervisor's recover() and the
encoder's stream-loss recovery now share failure backoff and a terminal-denial flag,
so a denied consent is not re-prompted by the other path.
Co-Authored-By: Claude Sonnet 5.5 <[email protected]>
* fix(control): keep unknown lock state unlocked, stop waits on Closing, never drop capture settings
- QuerySystemState with no logind lock state (Xvfb/linger) reports unlocked as before.
- The Portal wait loop also exits while the channel is Closing.
- Capture-setting requests back-pressure instead of try_send dropping the latest setting.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
---------
Co-authored-by: Claude Sonnet 5.5 <[email protected]>
Co-authored-by: VallierDev <[email protected]>
The root geometry and XShm image were read once at startup, so after a
RandR or xrdp resize every new connection asked x11grab for the old size
and stalled on "transferring picture". Query the root geometry before
each desktop connection and rebuild the capture when it changed; guard
capture with a lock and reject a stale-sized buffer instead of
overflowing it. The HEVC fallback log now includes the actual failure.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Unofficial Linux host for NetEase UU Remote: X11 (production-tested on
GNOME/Ubuntu 24.04), experimental Wayland (Hyprland) and portal
(GNOME/KDE) backends; video, input, clipboard, file transfer, terminal,
sound, quality/fps/resolution settings, lock/unlock and system actions.
Co-Authored-By: Claude Opus 5.5 <[email protected]>