Files
VallierDevandClaude Opus 5.5 aeaf818c39 Signaling: treat a connection without pings as dead and reconnect (#19)
Only a close frame or read error ended the signaling loop, so a half-open
socket after suspend or a NAT drop left the host believing it was online.
Per Engine.IO 4, report Disconnected when no ping arrives within the
server's pingInterval + pingTimeout so the existing reconnect loop runs.

Co-Authored-By: Claude Opus 5.5 <[email protected]>
2026-10-16 11:24:51 +08:00

1.1 KiB
Raw Permalink Blame History

信令断线检测:主机休眠恢复或网络悄悄断开后自动重新上线。/ Detect dead signaling connections and reconnect.

修复 / Fixed

  • 主机显示在线但控制端看不到、只能手动重启服务(#19,感谢 @Keinns):之前只有收到关闭帧或读错误才判定信令断开; 系统休眠恢复、NAT 超时等造成的半开连接会让主机一直以为自己在线。现在按 Engine.IO 协议,超过服务器下发的 pingInterval + pingTimeout(目前约 33 秒)没收到心跳就判定断线,走已有的自动重连。日志:Signaling heartbeat lost。 已用模拟的「不发心跳」信令服务器单元测试验证;真实休眠恢复场景未实测。 Signaling now treats a connection without pings for pingInterval + pingTimeout as dead and reconnects. Unit-tested against a silent mock server; real suspend/resume not yet measured.

下载 / Download

uu-remote-linux-v0.1.19-x86_64-linux.tar.gz:X11 版可执行文件(x86_64,glibc ≥ 2.35),附带 contrib/。

非官方项目,与网易无关。 / Unofficial, not affiliated with NetEase.